Does your FDA inspection plan need to be proactive first?

Maybe you need an FDA inspection plan. Does everyone in your company know what they need to do when FDA inspectors arrive at your facility?

Click here to subscribe to our blog feed

Be proactive and don’t just let FDA inspections happen. You need to have an FDA inspection plan, and that plan needs to cover the roles and responsbilities for everyone. Below we have a list of 15 items that are in our FDA inspection work instruction (WI-009). If you already have a plan, try using the following checklist to assess your readiness for the next next inspection:

  1. What will you ask and do when your FDA inspector calls the Friday before the inspection?
  2. Who should be contacted by the FDA inspector if you are on vacation?
  3. How will you communicate to the rest of your company that an FDA inspection is planned for Monday morning?
  4. Who will greet the FDA inspector upon arrival, and what should they do?
  5. Which conference room will the FDA inspector spend most of their time in?
  6. Who will be in the conference room with you and the FDA inspector?
  7. How will you track document and records requests, and how will you communicate that information to others?
  8. How will you retrieve documents and records requested by the FDA inspector?
  9. Who will conduct a tour of the facility with the FDA inspector and how will the tour be managed?
  10. When quality issues are identified, how will you respond?
  11. What will you do for lunches during the inspection?
  12. Who will attend the closing meeting with the FDA inspector?
  13. Should you “promise to correct” 483 inspection observations identified by the FDA?
  14. How and when will you repsond to the inspector with corrective action plans?
  15. If your company is outside of the USA, what should you do differently to prepare?

What will you ask and do when your FDA inspector calls the Friday before the inspection?

Most people begin their FDA inspection plan with the arrival of the inspector. However, you should consider including earlier events in your plan. Such as closure of previous 483 inspection observations, scheduling of mock-FDA inspections in your annual audit schedule, and details of how to interact with the inspector when they contact you just before an inspection. Most inspections will be conducted by a single inspector, but occasionally inspectors will be training another inspector. In this situation you can count on them following the QSIT manual more carefully, and you are more likely to receive an FDA 483 inspection observation. In the worst-case scenario, the lead inspector will split up from the trainee, and they will “tag-team” your company. This is not proper FDA procedure, but you should be prepared for that possibility. Therefore, make sure you ask the inspector if they are going to be alone or with another inspector when you speak with them on the phone. You should also get their name and phone number. You may even want to consider reviewing FDAZilla Store for details about your FDA inspector’s past inspection 483s and warning letters. Immediately after the call with the inspector, you should reserve a conference room(s) for the inspection and cancel your other meetings for the week. You should also verify that the person that contacted you is really from the FDA. You can do this by looking up their contact information on the Health and Human Services Directory. Your inspector should have a phone number and email you can verify on that directory.

Who should be contacted by the FDA inspector if you are on vacation?

You should always have a back-up designated for speaking with FDA inspectors, handling MDR reporting, and initiating recalls when you are on vacation. These are critical tasks that require timely actions. You can’t expect inspectors, MDRs, or recalls to wait you to get back in the office. It doesn’t matter what the reason is. Weddings, funerals, and ski trips should not be rescheduled. You need a back-up, and often that person is the CEO or President of your company. Make sure you have a strong systems in place (i.e. an FDA inspection plan, an MDR procedure, and a recall procedure). Whomever is your back-up needs to be trained and ready for action. This is also the purpose of conducting a mock-FDA inspection, including examples of MDRs in your medical device reporting procedure, and conducting mock recalls. This ensures you and your back-up are trained effectively. 

How will you communicate to the rest of your company that an FDA inspection is planned for Monday morning?

Most companies have an emergeny call list as part of their business continuity planning, and after the past 18 months of living with a Covid-19 pandemic your firm should certainly have a business continuity plan. Your FDA inspection plan should leverage that process. Contact the same people and notify them of when the FDA inspector is coming. If you are unable to find a conference room available for the inspection (i.e. see below), then ask the manager(s) that reserved the designated room for FDA inspections to relocate to another conference room for the week. Make sure you tell them who the inspector will be, and you might even be able to provide a photo of the inspector (try seraching LinkedIn). Make sure that you remind everyone to smile, and to listen carefully to the question asked. Everyone should be trained to answer only the questions asked, and nobody should run and hide. There should also be no need to stop your operations just because an inspector is visiting. You might even include the name of the inspector on a “Welcome Board” if your company has one at the entryway or in public areas. The more an FDA inspection appears as “routine” the better your outcome will be.

Who will greet the FDA inspector upon arrival, and what should they do?

By the time an FDA inspector(s) actually arrives at your company, all of the managers in your company should already been notified of the inspection and a conference room should be reserved for the inspection. Therefore, when the person that is greeting people in the lobby comes to work on Monday morning, you (or their supervisor) need to communicate with them and make sure that they are prepared for arrival. There are four things that should be communicated:

  1. the name of the inspector(s) that are arriving
  2. the list of managers that should be notified when the inspector(s) arrives (possibly identical to the buisness continuity call list)
  3. the conference room that is reserved for the inspection

If the person greeting the inspector(s) is also going to escort them to the conference room and help them get set-up, then they will need additional instructions. If that escorting inspectors to the conference room and helping them get set-up is delegated to a different person, then the following considerations should be included in that person’s instructions:

  1. the location of bathrooms and emergency exit instructions in case of a fire
  2. the information for wireless connectivity
  3. recommendations for seating in the conference room based upon the expected participants (see below)

It is important that an escort for the inspectors is able to bring the inspector(s) to the conference room as quickly as possible. They should not be expected to wait more than a few minutes for an escort.

Does your FDA inspection plan identify a specific room for the inspector? Is there a back-up?

Some companies have a specific room that is designated for inspections and 3rd party certification audits. If your comapny can do that, it will be very helpful because it reduces the decision making that is required immediatley prior to the inspection. Having a specific room for the inspection also eliminates the need to tell everyone else in the company where the inspector will be. Instead the location of the inspection can be in the work instruction or written FDA inspection plan. You shouldn’t need a back-up plan if there is a specific room designated for an FDA inspection, but our firm has a client that will be hosting three notified body auditors simultaneouly for three days. In that situation, you might need more than one room. 

Does your FDA inspection plan have assigned seating?

You might think that it really doesn’t matter where people sit in a conference room, but you will probably want consider the layout of charging cords and the flow of interviewees requested by the inspector. In your conference room, you will need room for at least the following people:

  1. the inspector(s)
  2. the management representative (i.e. you)
  3. a scribe
  4. an interviewee

If there is an inspector and a trainee, you will probably want to seat them together to facilitate them working together. You as the Management Representative also need to be in the room, and it may help for you to sit next to the scribe to facilitate communication between you and to make it easier for them to hand you documents after the scribe logs the documents into their notes. The scribe should probably sit closest to the door, because they will be receiving documents, logs, and records that are brought to the room. You will also need one more seat next to you, and probaby accross from the inspector(s), for interviewees. This person will rotate as different processes are reviewed. I also recommend having a location in the middle of the table for an “in box” where documents, logs, and records for the inspector are placed after being logged in. A second location in the middle of the table can be used for a “discard pile” as you finish using your copy of each document, log, and record. You may refer back to these copies later. The “discard pile” should be 100% copies rather than originals. Originals should never be brought into the room with the inspector.

Who is the scribe in your FDA inspection plan?

The perfect scribe would know the quality system well and they would have the typing skills of a professional stenographer. You might have someone that is an executive assistant in your company or a paralegal that could do this job, but you might also have a document control specialist that fits this requirement. Some companies will even hire a temp for the duration of the inspection that has this type of skill, but a temp is unlikely to know the jargon and quality system requirements well. I have taken on the role of scribe many times for my clients, because I type fast and know their quality system. I also don’t want to interferre with the inspection process. As scribe I can answer questions and offer suggestions when appropriate, but most of my time is spent taking notes and communicating by instant messenger with company members that are outside of the inspection room.

You should seriously consider using an application such as Slack as a tool for communication during the inspection. Then anyone in your company that needs to know the status of the inspection can be provided access to the Slack channel for the inspection. This can also act as your record of requests from the inspector. It’s even possible for people on the Slack channel to share pictures of documents to confirm that they have identified the document being requested. You could even invite someone to speak remotely with the inspector via Slack with Zoom integration. All the scribe needs to do is share the Zoom app with a larger display in the same conference room so the inspector can see it too.

Does your FDA inspection plan include provisions for  document and record retrieval?

The most important part of document and record retrieval during an FDA inspection is to remember that inspectors should never receive the original document. Ideally, a copier would be located immediately outside of the conference room and three copies would be made of every document before it enters the inspection room. The originals can be stored next to the copier until someone has time to return them to the proper storage location. The three copies should all be stamped “uncontrolled documents” to differentiate them from the originals. When the three copies are brought into the room, they should be handed to the scribe. The scribe should log the time the copies were delivered in the Slack channel. Then the copies should be handed to you, the Management Representative. You should skim the document to make sure that the correct document was received. Then one copy would be given to the inspector and another copy would be made available to the interviewee. If only two copies are needed, the extra copy can be placed in the “discard pile.”  Even if your system is 100% electronic, I recommend printing copies for the inspection. The paper copies are easier for inspectors to review, and it eliminates the ability for the inspector to hunt around your electronic document system. In this situation, the scribe may do all of the printing.

Does your FDA inspection plan indicate who will conduct a tour of the facility with the FDA inspector and how will the tour be managed?

I’m surprised by the number of companies that don’t seem to have a map of their facility. Medical device manufacturing facilities should have two kinds of facility maps. One should identify where pest control monitoring stations are located, and the second should indicate your evacuation route to exit the building. All guests should be shown the evacuation route map, probably within the first 30 minutes of arrival. The second map will be requested by the inspector eventually if you conduct manufacturing at your facility. Therefore, it would be helpful to use one or both of these facility maps as a starting point for creating a map of the route that inspectors should be taken on during a tour. I prefer to start with where raw materials enter the facility, and then I follow the process flow of material until we reach finished goods storage and shipping. If you can do this without back-tracking multiple times, then that will probalby be the preferred route. The purpose of planning the route out in advance is to help estimate how long the tour will take, and to make sure there is consistency. If someone starts the tour, and then another person takes over the tour, the new person should be aware of what the next location is and what areas have not been observed yet. There may also be safety reasons for avoiding certain areas during a tour and asking the inspector to observe those areas from a distance. Welding processes, for example, often fall into this safety category.

When quality issues (i.e. FDA 483 inspection observations) are identified, is this covered by your FDA inspection plan?

Third party certificaton body auditors will typically make you aware of nonconformities as they are identified, but FDA inspectors often will hold off on identifying 483 inspection observations until the end of the inspection in a closing meeting. However, you can typically identify several areas that may result in a 483 inspection observation during the inspection. You and the manager of that area may want to consider initiating a draft CAPA plan for each of these quality issues before the closing meeting. This would give you an opportunity to demonstrate making immediate corrections and you might be able to get feedback from the inspector on your root cause analysis and corrective action plan before the closing meeting. Sometimes this will result in an inspector identifying low-risk quality issues verbally instead of writing them out on FDA Form 483. I find the best way to make sure CAPA plans are initiated early is to have a debrief each day after the inspector leaves. All of the managers involved in the inspection should participate, and the debrief can be done virtually or in person. Virtually may be necessary, because often managers need to leave work before the inspector ends for the day. You should consider including this in your FDA inspection plan as well.

Does your FDA inspection plan include plans for daily lunches?

If your facility is located outside the USA, skip this paragraph and go to the section below about companies located outside the USA. If your company is locagted inside the USA, you can be certain that the FDA inspector will not eat lunch at your facility. They will leave for lunch on their own, and then they will return after lunch. Therefore, you may not have control of the timing of a lunch break but you will have time to take one. Most managers use the lunch break as a time to catch-up on emails. However, I think it makes more sense to change your email settings to “out of office.” You can indicate that you are hosting an audit and you will answer questions as a batch that evening or then next morning. You might use the lunch break to take a walk and relax, you might have  short debrief meeting with other managers, and you might spend some time preparing documents, logs, and records that the inspector may have requested before they left. Most inspectors use this strategy of asking for a list of documents and records in advance. This is also a good strategy to learn as an internal auditor or supplier auditor. If you have a back-room team that is supporting you, don’t make them wait for a break. Have someone in your company take their lunch orders or arrange for a catered buffet lunch. This will keep your support team happy, and you should definitely remember to include lunch for the team and changing your email settings to “out of office” in your FDA inspection plan.

Does your FDA inspection plan state who will attend the closing meeting?

Most companies have every manager that was in the opening meeting attend the closing meeting. This is ok, but it is important for anyone that might need to initiate a CAPA to be present in the meeting so that they can ask the inspector for clarification if needed. Scheduling a closing meeting should be part of your FDA inpsection plan. However, the past 18 months of the Covid-19 pandemic has taught us that we can attend this type of meeting remotely via Zoom. Therefore, we recommend letting the managers go home early if they are no longer needed as auditees. Instead, ask them to call in for a Zoom meeting at the time the FDA inspector estimates for review of the 483 inspection observations with the company.

Should you “promise to correct” 483 inspection observations identified by the FDA?

During the closing meeting the FDA inspector will review 483 inspection observations with you and any of the other managers present at the closing meeting. The inspector will ask if you promise to correct the 483 inspection observations that were identified. You should confirm that you will, and the FDA inspector will add this to the Annotations in the Observations section of FDA Form 483 that you will recive at the closing meeting. By stating this, you are agreeing to create a corrective action plan for each of the 483 inspection observations. You could change you mind later, but the better approach is to perform a thorough investigation of the 483 inspection observation first. If you determine that corrective action is not required, you can explain this in your CAPA plan and provide data to support it. The only likely reason for not correcting an observation is that you determined the incorrect information was provided to the inspector. In that case, you may need to do some retraining or organize your records better as a corrective action to prevent recurrence in a future inspection. You might even make modifications to your work instruction for “Conducting an FDA Inspection” (i.e. FDA inspection plan).

How and when will you repsond to the inspector with corrective action plans?

Your FDA inspection plan should include details on how respond to FDA 483 inspection observations and when the response must be submitted by. The FDA inspector will give you instructions for submission of your corrective action plans by email to the applicable email address for your region of the country. This email address and contact information should be added to your work instruction as an update after the first inspection if you are not sure in advance. You should respond with a copy of your CAPAs with 15 business days. Regardless of what the inspector told you, there is always a possibility that the outcome of your inspection could be “Official Action Indicated.” This is because the inspector’s supervisor makes the final decision on whether a Warning Letter will be issued and regarding the approval of the final inspection report. You should also confirm what the 15-day deadline is, because your state’s holidays may be different from the US Federal holidays.

If your company is outside of the USA, what should you do differently to prepare?

The US FDA only has jurisdiction over companies that are located in the USA. Therefore, if your company is registered with the FDA, you can only be inspected if you agree to host the FDA inspector when they contact you. FDA inspectors will contact foreign firms 6-8 weeks in advance, and they will typically give you a couple of weeks to choose from. After you confirm the dates for the inspection, then they will make their travel plans. Therefore, you will know exactly when the FDA inspection is schedulea and you will have more than month to prepare. Therefore, you should do four things differently:

  1. You should send the FDA inspector directions from the airport to your facility and provide recommendations for potential hotels to stay at. Ideally the hotels you recommend will provide transportation from the airport and managers that are speak passable English). The hotels should be appropriate for business travel–not royalty. If it is convenient, you may even offer to pick-up the inspector at the hotel each day to ensure they have no problems with local transportation.
  2. You should offer to provide lunches for the inspector during the inspection. This should not be considered entertainment. The purpose is make sure the inspector has lunch (i.e. a light meal or snacks) and drinks (i.e. water and coffee) during the inspection so that they do not have to negotiate local traffic, struggle with ordering food in a language they don’t know, and to eliminate delays associate with having lunch off-site. Make sure you remember to ask about food allergies and dietary restrictions. You might even follow-up with a draft menu to obtain confirmation that your proposed menu is appropriate.
  3. You should schedule a mock-FDA inspection immediately to verify that everyone is prepared and to identify any CAPAs that need to initiated before the FDA inspector finds the problems.
  4. During the first day of the inspection, you may consider asking the inspector if they would like to go out for dinner one of the evenings with a couple of people from your company or if they would like any recommendations for restaurants to eat at. If you are not familiar with US customs and international travel, ask the hotel concierge for advice. When you are out to dinner, the conversation should remain professional and if you normally drink alcohol at dinner you may want to consider the “BOB” compaign in the Netherlands as a role model. 

How are you going to train everyone in your company?

You need an easy way to train everyone in your company. Why not give them a video to watch? Next Monday, July 26, 2021 @ Noon EDT, we are hosting a webinar on how to prepare for an FDA inspection. It is a live webinar where you will be able to ask questions, and we are bundling the webinar with our new work instruction for “Conducting an FDA Inspection” (WI-009). If you register for the webinar, you will receive access to the live webinar, you will receive the native slide deck, and you will receive a copy of the work instruction. You can use the work instruction as an FDA inspection plan template for your company. The webinar will be recorded for anyone that is unable to attend the live session. You will be sent a link to download the recording to watch it as many times as you wish, and we recommend that you use the webinar as training for the rest of your company.

Does your FDA inspection plan need to be proactive first? Read More »

Are you a little curious, or fascinated by competitive warning letters?

Did you know you can download competitor inspectional observations to learn which quality issues are likely to result in warning letters?

Not long ago the FDA published their Inspectional Observation Data Sets. They are Excel spreadsheets of the dreaded 483 inspection observations and warning letters that the FDA issues after performing inspection of manufacturers. There is a spreadsheet for each of the following topic areas, and we will take a look at the ‘Devices’ observations. A post-mortem data analysis or speculative data autopsy if you will… What can we learn when examining an FDA inspection observation?

Click here to subscribe to our blog feed

  • Biologics
  • Drugs
  • Devices
  • Human Tissue for Transplantation
  • Radiological Health
  • Parts 1240 and 1250
  • Foods (includes Dietary Supplements)
  • Veterinary Medicine
  • Bioresearch Monitoring
  • Special Requirements
  • Total number of inspections and 483s

These are nonconformities written by the FDA to the Code of Federal Regulations, so there won’t be any statistics for ISO 13485:2016 or Regulation (EU) 2017/745. There will be lots of findings under the ‘QSR’ or 21 CFR 820. The good news, unlike an ISO Standard, is that the Code of Federal Regulations is publicly available online for free. It isn’t a pay-to-play game and we can share the full text of the requirement without violating any copyright licensing agreements. 

The top 10 areas for inspection observations and warning letters are: 

  1. CAPA procedures
  2. Complaint procedures
  3. Medical Device Reporting
  4. Purchasing Controls
  5. Nonconforming Product
  6. Process Validation
  7. Quality Audits
  8. Documentation of CAPA actions and results
  9. Training
  10. Device Master Record

Corrective and preventive action is the most common reason for warning letters

The winning quality system requirement that resulted in the most 483 inspection observations and warning letters was for Corrective and Preventive Actions under 21 CFR 820.100(a). This finding is listed when a manufacturer fails to establish a CAPA procedure or the procedure is inadequate. This finding was cited 165 times. In addition, CAPA activities or their results were not documented or were not documented adequately a total of 32 times under 21 CFR 820.100(b). This gives us a grand total of 197 observations for the CAPA process.

Corrective and preventive actions are either fixing an identified problem and making sure it doesn’t happen again, or stopping a potential problem from happening in the first place. It is both the reactive and proactive response for quality issues and product non-conformance. The text of the requirement is:

“§820.100 Corrective and preventive action.
(a) Each manufacturer shall establish and maintain procedures for implementing corrective and preventive action. The procedures shall include requirements for:
(1) Analyzing processes, work operations, concessions, quality audit reports, quality records, service records, complaints, returned product, and other sources of quality data to identify existing and potential causes of nonconforming product, or other quality problems. Appropriate statistical methodology shall be employed where necessary to detect recurring quality problems;
(2) Investigating the cause of nonconformities relating to product, processes, and the quality system;
(3) Identifying the action(s) needed to correct and prevent recurrence of nonconforming product and other quality problems;
(4) Verifying or validating the corrective and preventive action to ensure that such action is effective and does not adversely affect the finished device;
(5) Implementing and recording changes in methods and procedures needed to correct and prevent identified quality problems;
(6) Ensuring that information related to quality problems or nonconforming product is disseminated to those directly responsible for assuring the quality of such product or the prevention of such problems; and
(7) Submitting relevant information on identified quality problems, as well as corrective and preventive actions, for management review.
(b) All activities required under this section, and their results, shall be documented.
“

We can see that under section (a) the requirement is that there is an established and maintained process control with a numerical list of required inputs and outputs of that process. The process control is easy, use a procedure. You have to establish a procedure and you have to maintain it. That is one part of the first 165 observations.

The second part is that the procedure needs to be ‘adequate’. That means that bullets (1)-(7) need to be addressed within that procedure. For example number (2) is “Investigating the cause of nonconformities relating to product, processes, and the quality system;”. This means that the procedure should be explaining not only that your quality system will be doing that investigation, but who will be doing it and how they will be doing it. 

“The cause of nonconformities shall be investigated”, may not be an adequate process control. Yes, it addressed the need for a root cause evaluation, but does it do that adequately? 

“The RA/QA Manager will complete or assign a staff member to complete the root cause evaluation of Corrective Actions utilizing methods such as a ‘5-Why Analysis’ by filling in section 2. Of the CAPA report form.” This wording is much closer to what is needed in a procedure. It explains who is doing what, roughly how they might do it, where that activity gets documented and identifies the record that the activity produces.

Which brings us to the extra 32 findings where the activities and their results either weren’t documented or were done so poorly. This is why identifying the input (Root Cause Analysis) and the output (Section 2. of the CAPA report) are important. It allows you, the inspector or an auditor to trace from the procedure to the record that part of the process produces to demonstrate conformity. 

As the age old saying goes, “if it isn’t documented, it didn’t happen”. That record should show that yes you did a root cause analysis (the activity) and what the conclusion of that analysis was (the results of that activity). These types of records are so vital to your quality system that there is an entire process dedicated to the control of records. I’ll give you a hint, it is Subpart-M of the QSR. 

This is also a great segway to show how the processes go hand in hand and CAPA is interrelated to Document Control, Record Control, and your Quality System Record. Your system processes will continually wrap back around to each other in this manner. For example, CAPAs are a required input into your Management Review process so if you don’t have a CAPA procedure you aren’t performing adequate management reviews. 

A note on other systems

If your quality system is also ISO 13485:2016 compliant, Corrective Actions and Preventive Actions are separate items under separate sub-clauses. Corrective Actions are in 8.5.2., and Preventive Actions are in 8.5.3. Meaning if you have a mature quality system that has never had a preventive action, then your CA might be fine, but the PA of that process may be inadequate.

An industry standard for CAPAs is applying a risk based approach, and we have an entire webinar dedicated to the subject! How to create a risk-based CAPA process

Complaints are the second most common reason for warning letters

Hand pressing red complaint button

The silver medal goes to complaints. Much like CAPA the biggest issue is no, or inadequate complaint handling procedures. This specific finding was cited 139 times (overall complaint handling has more but this specific issue was the most cited). Not to sound like a broken record but again, complaint handling is a specific process that requires an ‘established and maintained procedure”.

As a procedure it has to exist, it has to be maintained, and each process has requirements for inputs and outputs that must be outlined. Complaint handling is a little bit different in the QSR in that there isn’t a ‘complaint’ sub-part. Complaints are under Sub-Part M- Records, specifically 21 CFR 820.198 Complaint Files. 

To compare, Complaints in accordance with ISO 13485:2016 are under Measurement Analysis and Improvement, specifically Sub-clause 8.2.2. Complaint Handling. It is sandwiched in between Feedback and Reporting to Regulatory Authorities. That had to have been done on purpose because those processes are inherently intertwined and their inputs and outputs directly feed into each other:

“§820.198 Complaint files.
(a) Each manufacturer shall maintain complaint files. Each manufacturer shall establish and maintain procedures for receiving, reviewing, and evaluating complaints by a formally designated unit. Such procedures shall ensure that:
(1) All complaints are processed in a uniform and timely manner;
(2) Oral complaints are documented upon receipt; and
(3) Complaints are evaluated to determine whether the complaint represents an event which is required to be reported to FDA under part 803 of this chapter, Medical Device Reporting.
”

This sub-section of ‘Records’ may be less intuitive than what we saw under CA/PA. We can see that we have to maintain complaint files. We also need a procedure that covers receipt, review, and evaluation of complaints. Then we have to name a formally designated complaint handling unit to do all of that. 

Further we need to make sure that complaints are handled uniformly and efficiently. It should be a cookie cutter process with a known timeline. Every complaint goes through the same review and evaluation within a specific time period. If it takes six months to review a complaint, that definitely is not a ‘timely manner’. 

Not every complaint will be sent to you via certified mail with ‘Complaint’ written across the top in big BOLD letters. Sometimes people will simply tell you about a complaint they have verbally and your process needs to define how it is addressing these verbal communications. Otherwise your FDA inspection observation will be written, and you run the risk of receiving warning letters.

This of course begs the question, what is a complaint? How will I know if I received one? Fortunately 21 CFR 820.3 provides us with definitions, one of them being what exactly a complaint is “(b) Complaint means any written, electronic, or oral communication that alleges deficiencies related to the identity, quality, durability, reliability, safety, effectiveness, or performance of a device after it is released for distribution.”.

There is no quiz at the end of this but I would caution you that this will probably be on the test. Anytime you ask a question like that and the regulation provides a definition for it, then it’s a good idea to include that definition within your procedure. This is a way to make sure that there is uniformity in the understanding of a procedure. If you miss a complaint because you didn’t realize that it was a complaint then your process is not effective. Eventually an auditor will pick up on the deficiencies in the process, document a finding and you will be doing a CAPA to fix it.   

Every complaint needs to be reviewed, but not every complaint needs to be investigated. This was a much less cited issue (5). You are allowed to decide that an investigation isn’t needed. However, if you do then you must keep a record of why you decided that and name the person responsible for that decision. 

That isn’t carte’ blanche to just write off investigations whenever you want. There are some things that require an investigation and there is no accepted rationale for not performing one. An example is when there is a possible failure of a device, it’s labeling or packaging to meet any of their specifications. Those need to be investigated without exception. What your system is allowed to do though is if you have already done an investigation and you received related similar complaints, there is no need to repeat the same investigation for every complaint. 

An important concept of complaint handling is that you should be triaging your complaints as you receive them. There are certain types of complaints that must be reported to the FDA. More information is actually found under 21 CFR 803, not the 820 that we have been examining. These special complaints need to be identifiably separate from your normal run of the mill complaints. These complaints specifically need a determination of; 

  • Whether the device failed to meet specifications;
  • Whether the device was being used for treatment or diagnosis; and
  • The relationship, if any, of the device to the reported incident or adverse event.

Outside of those special reportable complaints, all investigations have certain required outputs. By addressing every complaint in a uniform repeatable manner, this can be boiled down to a form. In fact creating a specific complaint form makes sure that all of the required information has been documented. Each record of an investigation by your formally designated complaint handling unit has to be include;

  • The name of the device;
  • The date the complaint was received;
  • Any unique device identifier (UDI) or universal product code (UPC), and any other device identification(s) and control number(s) used;
  • The name, address, and phone number of the complainant;
  • The nature and details of the complaint;
  • The dates and results of the investigation;
  • Any corrective action taken; and
  • Any reply to the complainant.

Some companies and corporations sprawl across the globe and have many sites all over the place. Not every manufacturer is limited to containing all of their operations within a single building. There are times where the formally designated complaint handling unit may be somewhere other than where the manufacturing is taking place. That is acceptable as long as communication between the two is reasonably acceptable. The manufacturer needs access to the records of the complaint investigations performed. Just as everything must be documented, all of that documentation must be producible as well. If not, your inspector will produce FDA 483 inpsection observations and warning letters.  

If the complaint handling unit is outside of the United States the records have to be accessible in the United states from either the place where the manufacturers records are normally kept or at the initial distributor. 

Complaint Handling and vigilance reporting are topics that we often find stuck together like velcro. We find them so interelated that we have a combined Complaint Handling and Vigilance Reporting Webinar.

Medical Device Reporting is the third most common reason for warning letters

The bronze medal recipient shows a drop in sheer numbers of FDA inspection observations. A total of 68 were written for the fiscal year of 2020, and these findings have a high likelihood of resulting in warning letters because these incidents may involve serious injuries and death. We are slowing down, but this is still a topic that gets an FDA inspection observation almost every week.

But again part of the issue is no, or bad procedures to control this process. Not to be confused with the (EU) MDR since as an industry we love acronyms so much, Medical Device Reporting is referenced within the Quality System Requirements of 21 CFR 820. We took a peek above in Complaint Handling. What makes this unique is that MDR actually lives in 21 CFR 803 Medical Device Reporting. What makes it even more special is that Part 803 is further broken down into sub-parts. 

We will take a look at Sub-part E which is the reporting requirements for manufacturers. Medical Device Reporting is a process and as such needs a procedure to control it and that procedure must be maintained. 

Some key points to capture is that there are reporting timelines that are measured in calendar days from when you become aware of information that reasonably suggests that one of your devices;

“(1) May have caused or contributed to a death or serious injury or
(2) Has malfunctioned and this device or a similar device that you market would be likely to cause or contribute to a death or serious injury, if the malfunction were to recur
.”

There are some crucial takeaways. First, the clock starts ticking down calendar days, not work days, and holidays count. You can’t hold off reporting that your device killed someone because it’s around the holidays and over a few weekends. 

Second, is that reporting timelines vary, generally between 5 and 30 calendar days. That means it is important to know the specific timeline for the type of report you are making and what the authority having jurisdiction requires for a timeline. The FDA may differ from Health Canada which in turn may differ from the EU, etc. 

Third is that the bar to meet is what would be ‘reasonably known’, and that is somewhat of an ambiguous requirement open to interpretation.

They help clarify this with,

“(i) Any information that you can obtain by contacting a user facility, importer, or other initial reporter;
(ii) Any information in your possession; or
(iii) Any information that you can obtain by analysis, testing, or other evaluation of the device.
”

The first two are usually not an issue, but the one that tends to get less attention is deeper analysis, testing or evaluation of the device. Due diligence is required here to make sure that you actually do know the information that should be ‘reasonably known’ to you. 

The burden of investigation and root cause determination is placed squarely on the shoulders of the manufacturers and that is a process that can take some time. What happens when the reporting timely is fast approaching but your investigation won’t be finished before the clock runs out? The short answer is to report it anyway.

The longer answer is to report what information you do have with an explanation of why the report doesn’t have all of the required information. Then explain what you did to try to get all of the information, and file a supplemental or follow-up report later to fill in the gaps. Only having a partial report ready is not an excuse to miss the reporting deadline. It is however, the perfect excuse to get an FDA inpsection observation or warning letters.

Are you a little curious, or fascinated by competitive warning letters? Read More »

What’s the difference between PMS, PSUR, and PSR?

This blog is intended to help clear your justified confusion if you are wondering what the difference is between PMS, PSUR, and PSR.

 

The nine most terrifying words in the English language are, “I’m from the Government, and I’m here to help.” That quote is from a speech by President Reagan on August 12, 1986.  One of the goals of the European Parliament and Council was “to ensure effective coordination of [competent authority] market surveillance activities and to clarify the applicable procedures.” After studying the new European MDR, I can confidently say that the European Parliament and Council have done their job well. My boss is a regulatory consultant with 30 years of experience, and he asked me to explain the difference between PMS, PSUR, and PSR.

Click here to subscribe to our blog feed

To answer that question as objectively as possible, and cite my sources, I have included a copy and paste directly from Regulation (EU) 2017/745. Red text is my commentary, while the italicized text is a quotation from the most relevant article within the new EU regulations.

Under the New MDR, the only Class IIa, Class IIb, and Class III products are definitively required to have a Periodic Safety Update Report (PSUR). The PSUR needs to be updated annually for Class III and Class IIb implants, and the PSUR needs to be updated at least every two years for Class IIb (non-implants) and Class IIa devices. The PSUR must be available to your notified body, and upon request, the competent authorities. In contrast with the PSUR, Post-Market Surveillance (PMS) reports are required for Class I devices. Finally, a manufacturer’s Periodic Summary Report (PSR), relates to specific cases of Serious Incidents and Field Safety Corrective Actions (FSCA’s) based upon an agreement between the manufacturer and the competent authority or authorities instead of submitting individual FSCA reports.  This is confusing because the PSUR also meets the requirements of a PMS Report as defined in Article 85, but we don’t call it a PMS Report.

“Article 83 – Post-market surveillance system of the manufacturer

1. For each device, manufacturers shall plan, establish, document, implement, maintain, and update a post-market surveillance system in a manner that is proportionate to the risk class and appropriate for the type of device. That system shall be an integral part of the manufacturer’s quality management system referred to in Article 10(9).”

In Matthew’s words, “Manufacturers are required to establish a PMS system for every device or device family.”

“Article 84 – Post-market surveillance plan

The post-market surveillance system referred to in Article 83 shall be based on a post-market surveillance plan, the requirements for which are set out in Section 1.1 of Annex III. For devices other than custom-made devices, the post-market surveillance plan shall be part of the technical documentation specified in Annex II.”

In Matthew’s words, “Article 84 requires you to have a PMS plan in your quality system.”

“Article 85 – Post-market surveillance report

Manufacturers of class I devices shall prepare a post-market surveillance report summarizing the results and conclusions of the analyses of the post-market surveillance data gathered as a result of the post-market surveillance plan referred to in Article 84 together with a rationale and description of any preventive and corrective actions taken. The report shall be updated when necessary and made available to the competent authority upon request.”

In Matthew’s words, “A Class I device requires a PMS report, while the other product classifications require a PSUR.”

“Article 86 – Periodic safety update report

1.1 – Manufacturers of class IIa, class IIb, and class III devices shall prepare a periodic safety update report (‘PSUR’) for each device and were relevant for each category or group of devices summarizing the results and conclusions of the analyses of the post-market surveillance data gathered as a result of the post-market surveillance plan referred to in Article 84 together with a rationale and description of any preventive and corrective actions taken. Throughout the lifetime of the device concerned, that PSUR shall set out:

(a)

the conclusions of the benefit-risk determination;

(b)

the main findings of the PMCF; and

(c)

the volume of sales of the device and an estimated evaluation of the size and other characteristics of the population using the device and, where practicable, the usage frequency of the device.

Manufacturers of class IIb and class III devices shall update the PSUR at least annually. That PSUR shall, except in the case of custom-made devices, be part of the technical documentation as specified in Annexes II and III.

Manufacturers of class IIa devices shall update the PSUR when necessary and at least every two years. That PSUR shall, except in the case of custom-made devices, be part of the technical documentation as specified in Annexes II and III.

For custom-made devices, the PSUR shall be part of the documentation referred to in Section 2 of Annex XIII.

  1. For class III devices or implantable devices, manufacturers shall submit PSURs by means of the electronic system referred to in Article 92 to the notified body involved in the conformity assessment in accordance with Article 52. The notified body shall review the report and add its evaluation to that electronic system with details of any action taken. Such PSURs and the evaluation by the notified body shall be made available to competent authorities through that electronic system.
  2. For devices other than those referred to in paragraph 2, manufacturers shall make PSURs available to the notified body involved in the conformity assessment and, upon request, to competent authorities.”

In Matthew’s words, “Barring specified exemptions, manufacturers of a Class IIa device would need to submit a PSUR and update it at least every two years.”

“Article 87 – Reporting of serious incidents and field safety corrective actions

9. For similar serious incidents that occur with the same device or device type and for which the root cause has been identified or a field safety corrective action implemented or where the incidents are common and well documented, the manufacturer may provide periodic summary reports instead of individual serious incident reports, on condition that the coordinating competent authority referred to in Article 89(9), in consultation with the competent authorities referred to in point (a) of Article 92(8), has agreed with the manufacturer on the format, content, and frequency of the periodic summary reporting. Where a single competent authority is referred to in points (a) and (b) of Article 92(8), the manufacturer may provide periodic summary reports following an agreement with that competent authority.”

In Matthew’s words, “Periodic summary reports (PSRs) refer to significant incidents (SIs) and field safety corrective actions (FSCAs). PSRs require an agreement between the manufacturer and the competent authority(s) for cases where there is a group of common, well-known, and documented SIs or FSCA’s with a known root-cause. PSRs are an alternative to submitting individual SI and FSCA reports.”

Additional Quality System Resources

My boss also asked me to update the procedures for post-market surveillance (SYS-019) and vigilance (SYS-036). The PMS procedure includes requirements for Articles 83-86. The vigilance procedure includes the requirements for Articles 87-92.

About the author

Matthew Walker – QMS, Risk Management, Usability | Human Factors Engineering, Cybersecurity & DFIR

Matthew brings a unique background as a former Firefighter/EMT and Rope Rescue Tech with experience in OSHA and NFPA regulations. For the better part of a decade, he has worked as a Technical/Medical Writer and Lead Auditor. He holds degrees in Fire Science and Computer Forensics and Digital Investigations, graduating Summa Cum Laude from Champlain College. Matthew is also an active member of several academic honor societies including Omicron Sigma Sigma’s Order of the Sword and Shield. His professional focus includes Human Factors Engineering, Risk Management, and Cybersecurity with a special interest in applying Digital Forensics and Incident Response (DFIR) practices to medical technology. He combines regulatory expertise with technical insige to strengthen both product safety and oranizational resiliance. He can be reached by email. You can also follow him on LinkedIn or YouTube.

What’s the difference between PMS, PSUR, and PSR? Read More »

Changes triggered by COVID19 in your quality system

The 2020 global pandemic has changed life as we know it, but this article focuses on three crucial quality system changes triggered by COVID19.

There are three (3) changes triggered by COVID19: 1) PPE, 2) business continuity plans, and 3) remote auditing.

Last night my daughter Gracie mentioned that her teacher assigned an essay to write about three changes triggered by COVID19 in her life. The three things that she felt had changed the most were: 1) she goes to bed much later, and sleeps in every day; 2) her school is closed, and she only talks to her teacher twice per week via Zoom, and 3) she misses her friends. I know that her story is similar to my son Bailey who is in his Freshman year of college, and I know that my personal story is quite similar. Coincidentally, I started writing this article earlier this week about three significant-quality system changes triggered by COVID19:

  1. If you are going to conduct on-site audits, you need to ask about using personal protective equipment (PPE).
  2. There needs to be a greater focus on business continuity plans and robust supply chain monitoring.
  3. Remote audits are suddenly encouraged for 1st, 2nd, and 3rd-party audits.

Click here to subscribe to our blog feed

Changes triggered by COVID19: #1 Use Face Masks

US FDA Issues EUAs

At the beginning of the COVID19 pandemic, the US FDA created several emergency use authorizations (EUA). The three EUA areas were IVD testing, ventilators, and face masks. The EUA for IVD testing is not surprising, because the FDA issues and EUA every time a new lethal and contagious virus emerges (e.g., Zika and Ebola). The EUA for ventilators was issued because the number of people with respiratory issues was expected to explode with the spread of the virus, and the supply chain for components of ventilators had already been disrupted by the initial spread of the virus in China. The EUA for face masks was issued because it is the second-best way to protect people from the virus, and existing infrastructure for face mask production could not possibly supply the entire world with face masks overnight.

Everyone in the World Gets a Face Mask

As soon as the EUA for face masks was issued, every regulatory consultant in the USA was inundated with urgent requests for help to complete EUA requests for masks. I also received similar requests for assistance with Canadian filings. The FDA did a great job of providing detailed information about the different types of face masks (i.e., face masks, surgical face masks, and N95 respirators). Testing companies created new website pages specifically for each of the different face mask tests, and every company with a sewing machine suddenly wanted to manufacture masks. I even read an article about an elderly woman making face masks for her entire family while she listened to The Beatles “HELP!” in the background.

Why aren’t you wearing your face mask?

Even after the world makes the first 7 billion face masks, not everyone will wear their face masks. Masks will protect us from touching our hands to our face–which spreads many germs in addition to the SARS-CoV-2 virus. Masks will also keep us from coughing on other objects and people if we have the virus. Finally, face masks protect us from the small droplets that carry the virus from one person to the next. Even though there are obvious safety reasons for everyone in the world to wear a face mask, most people don’t want to wear a face mask. This is no different from the argument to wear a seat belt, and unless our government creates a law or temporary order requiring us to wear face masks, most people won’t bother to wear one.

Changes triggered by COVID19: Auditors need to wear face masks 

As a medical device auditor, I feel I must always follow the safety rules in every facility I visit. Lead auditors are supposed to contact the company ahead of time and ask about the safety policies as part of audit preparation and initiating the audit. I’m 6’6” (2.00m) in height, and my shoe size is 14. There is seldom gowning for me to wear that fits appropriately–especially in Southeast Asia. I squeeze into the garments, and they are uncomfortable and hot, but I wear the garments anyway. My job includes auditing clean rooms, and I can’t do my job without gowning up. By following the rules, I also eliminate the excuses for anyone in the facility I visit. Now that we have a global pandemic, you should be wearing a face mask in every medical device facility to protect yourself, people you work with, and users of medical devices. You should also consider carrying spare face masks with you to protect yourself on airplanes, in hotels, etc.

Changes triggered by COVID19: #2 Business Continuity Plans

Will business continuity plans be required now?

In addition to the cultural shift to wearing face masks, we will also need to make significant changes in our overall preparations for natural disasters, fires, and biological threats. Although there is no specific requirement for a business continuity plan in ISO 13485:2016, there are many places where an auditor can identify a requirement to maintain the effectiveness of a quality system (no exceptions):

  1. Clause 1, Scope
  2. Clause 4.1.1 & 4.1.3, General Quality System Requirements
  3. Clause 5.3, Quality Policy
  4. Clause 5.4.2, Quality management system planning
  5. Clause 5.6.3, Management Review Output
  6. Clause 6.1, Provision of resources
  7. Clause 8.1, General requirements for Measurement, analysis, and improvement
  8. Clause 8.2.4, Internal audit
  9. Clause 8.5.1, General Improvement

Although any of these clauses could potentially be referenced as a requirement for a business continuity plan, the last clause would generally be the most appropriate. This clause states, “The organization shall identify and implement any changes necessary to ensure and maintain the continued suitability, adequacy and effectiveness of the quality management system…”. In this time of radical change, adding provisions to your business continuity plan for coping with a global biological threat seems obvious and urgently needed.

Suggested content for your business continuity plan

Sadly, the USA was probably better prepared for a disaster in the 1960s after the Cuban Missile Crisis than we are today. If you do not yet have a business continuity plan, or if you need suggestions for improving your plan, the following is a list of suggested items to include in your plan:

  1. Develop a plan for power outages, fires, floods, earthquakes, severe wind/tornadoes, hurricanes, workplace violence, and biological threats 
  2. Develop an emergency alert system to notify employees of any emergency
  3. Build emergency kits and store the kits for when they are needed
  4. Document your plan in multiple formats (virtual and physical) and distribute to all employees–including a social media plan
  5. Translate your plan into multiple languages for non-English speaking employees
  6. Develop a training program that addresses the various aspect of emergency preparation
  7. Practice your plan just like fire drills, so everyone is prepared and nobody panics

The Ready.gov website has many resources for the above items, including a series of “Ready Business Videos” and “Ready Business Toolkits.”

How to practice your business continuity plans

My sister is a teacher, and she is in the process of opening a new charter school in Maine. We were discussing her planning for the school, and the disruption of schools by the COVID19 pandemic has challenged all teachers to learn to use distance learning. My sister’s school focuses on teaching children about the environment, and she doesn’t like to spend lots of time on the computer. I was sharing some of the environmental studies my daughters are receiving via Zoom from their teachers. I suggested that she might want to pick one topic each week to teach via distance learning. The purpose of this would be to give her, and her students practice using distance learning for a variety of subjects. Therefore, when we experience another biological disaster, her students will already know precisely how to use distance learning to continue their education. My argument was that this routine use of distance learning would be a more effective preparation for emergencies than a once-per-month “fire drill.” Companies should use the same approach. Your company should create a schedule for practicing remote management meetings and working from home. This will ensure that systems are in place to keep your business running smoothly when disaster strikes again.

Changes triggered by COVID19: Expect regulators to require business continuity plans

The widespread shortage of face masks, ventilators, and other critical supplies needed during the COVID19 pandemic is going to result in new regulations requiring business continuity plans. This is a certainty born from the observation that every single medical device regulation we have resulted from severe public health threats. The COVID19 pandemic is the biggest global health crisis the world has experienced in 100 years. Therefore, we can expect corrective actions in the form of new regulations requiring companies to have a business continuity plan. Some regulators will act independently, but I would expect this also to be an action taken by the International Medical Device Regulators Forum (IMDRF). We can also expect there to be new laws requiring amendments to business continuity plans for public companies. The Sarbanes-Oxley Act of 2002 requires public companies in the USA to have business continuity plans. Despite this requirement, many public companies have been ruined by the COVID19 pandemic. Therefore, we should expect amendments to these requirements and revisions to the international standard for business continuity planning (i.e., ISO 22301:2019). We should also expect to see new interest in becoming certified to this standard.

Changes triggered by COVID19: #3 Remote Auditing

What are certification bodies doing about surveillance audits and re-certification audits?

Most of the companies that had initial certification audits scheduled for the first quarter of 2020 were forced to reschedule their audits because the employees must work from home, and the certification bodies must conduct at least some of their audits on-site. The FDA was also forced to cancel all foreign inspections temporarily. However, companies that already have certification need surveillance audits and re-certification audits to maintain the validity of their quality system certificates. Therefore, certification bodies now have plans for conducting audits remotely. For companies that virtual medical device manufacturers, certification bodies can conduct full quality system audits remotely. However, manufacturers with production activities on-site are only able to conduct partial audits. The certification bodies must still conduct on-site audits, but they are being permitted six months to conduct an on-site audit to cover the gaps remaining from the partial remote audits. Prior to conducting the partial remote audits, certification bodies are sending out questionnaires to all of their clients to gather information about whether the manufacturers can support a remote audit and to what degree.

Second-party audits conducted remotely

Second-party audits, also known as supplier audits, have always been of interest for manufacturers to conduct remotely–mainly if the supplier is located overseas. The US FDA regulations do not require companies to conduct supplier audits. However, if there are quality problems with suppliers, you are expected to conduct a thorough investigation to identify the root cause of quality problems, in most cases, that require an on-site audit. However, if your suppliers are providing good quality and they are ISO 13485:2016 certified, then you probably are using this as a justification for not conducting on-site audits or at least reducing the frequency of those audits. Now that most people are not able to travel, or because the people you need to speak with are working from home, manufacturers are being forced to conduct remote audits. This has always been permitted, but the effectiveness of remote audits is often questioned. Supply chain disruptions are now a global issue that is impacting the safety and effectiveness of our hospitals, and regulators will expect you to improve the rigor of your supplier evaluations–including conducting more supplier audits. Therefore, establishing more effective procedures for remote supplier auditing is urgently needed.

Changes triggered by COVID19: We need to develop procedures for remote auditing

Although most first-party audits are conducted on-site, especially if conducted by employees of your company, we will still need to establish procedures for remote auditing for internal audits. Some of our client’s scheduled internal audits for April and May that they had to cancel because they were unable to access the records needed for the audit while they were working from home. In addition, most of the US States have implemented stay-at-home audits that prevent our team from traveling to our clients. This is forcing our team to develop more robust procedures for remote auditing. We needed to change our audit agendas to accommodate eight 90-minute audit sessions in four days, instead of conducting two full days of on-site auditing. We are also doing more preparation before the audit to allow the auditees time to scan paper records so that we can review those records remotely. Finally, we are experimenting with techniques for collaboration as an audit team so that multiple auditors can simultaneously audit a client and complete a full quality system audit more quickly without forcing any one person to work for longer than 90 minutes in front of a computer. We are still perfecting these new methods, but we are writing a series of articles on this topic. You can order the book from Amazon ($5 pre-order discount until August 28, 2020).

Thank you & Future Articles

Thank you for reading. This is the longest article we have published on our site since 2012. This article also kicks off a ten-part blog series specific to remote auditing techniques:

  1. Remote audit opening meeting – 4 changes – May 12
  2. Audit team communications – May 19
  3. Remote audit resources – software and hardware tools – May 26
  4. How to apply a risk-based auditing approach to audits and remote audits – June 2
  5. How to make a supplier questionnaire for remote auditing – June 25
  6. Remote audit duration less than 90 minutes – June 30
  7. Remote auditing work instruction – July 14
  8. Planning partial remote audits – July 21
  9. Remote audit invitations – 4 things to remember – August 4
  10. Training new audit team members and lead auditors – August 11

There are also five new live webinars planned on related topics:

  1. Opening Meetings Webinar (free) – May 14, 2020
  2. Audit team communication during a remote audit (free) – June 4, 2020
  3. How to qualify your supplier’s Webinar (pre-order by June 1) – June 25, 2020
  4. Remote auditing techniques webinar (pre-order by July 1) – July 16, 2020
  5. MDSAP Certification Body Interviews (free) – August 6, 2020

Changes triggered by COVID19 in your quality system Read More »

NSE letter: A CAPA plan for your 510k process

Cry, complain, call the reviewer…you might feel a little better, but you received an NSE letter, and tomorrow you still can’t sell your device.

NSE Letter

Instead, try approaching an NSE letter like a CAPA investigation. What is the issue? The FDA determined that your device is not substantially equivalent to the predicate you selected. What is the root cause? There are four (4) possible root causes.

Click here to subscribe to our blog feed

NSE Letter Cause #1: You failed to verify that the predicate is a legally marketed device.

If your predicate device is not legally marketed, you need to select a new predicate and resubmit. However, it is doubtful that your device would pass the refusal to accept the (RTA) screening process if the predicate was not legally marketed. If your predicate was not registered and listed with the FDA (check using this link), then you should have submitted a pre-sub request to determine if the agency has any problem with using the device you chose as a predicate. This is an essential question if the manufacturer is no longer in business, and the product is no longer for sale.

NSE Letter Cause #2: You failed to evaluate the substantial equivalence of your device’s intended use with the predicate.

The intended use of your predicate device is documented for every potential predicate since February 1992 on FDA Form 3881–which you can download along with the 510k clearance letter for the predicate. There is also an intended use documented for every device category in the applicable regulation for that device. This intended use is more generic than FDA Form 3881, but both are applicable. The FDA Form 3881 you submit for your device must be equivalent. I recommend a point-by-point comparison with regard to the following elements: 1) OTC vs. prescription use, 2) user, 3) patient population, 4) illness or medical condition, 5) duration of use, 6) environment of use and 7) target part of the body. Any difference can raise new issues of risk and may result in an NSE decision. However, the FDA typically will work with the company to modify the wording of FDA Form 3881 to ensure the intended use is equivalent or to make sure you provide clinical evidence to address the differences. In my pre-submission requests, I include a comparison document for the intended use to ensure that the FDA is aware of any differences in the intended use.

Cause #3: You failed to convince the FDA that technological differences do not raise different questions of safety and effectiveness.

Unless your device is identical in every way to the predicate device, you will have to persuade the FDA that differences do not raise questions of safety and effectiveness. At the beginning of the 510(k) process, it is helpful to document technological differences systematically. Specifically, this should include: 1) materials, 2) design, 3) energy source, and 4) other features. For each difference, you must justify why the difference does not raise different issues, or you must provide data to prove it. It is also possible that you were not aware of questions of safety and performance raised by technological differences. To avoid this problem, you can submit a detailed device description and draft labeling to the FDA in a pre-sub meeting request. If you ask questions about differences in a pre-sub meeting, you can avoid an NSE letter.

Cause #4: You failed to provide data demonstrating equivalence.

For each difference, you should determine an objective method for demonstrating that the difference is equivalent in safety and performance to the predicate. Your test method can be proposed to the FDA in a pre-sub request before testing. The FDA sees more than 3,000 companies propose testing methods to demonstrate equivalence each year. They have more experience than you do. Ask them in a pre-sub before you test anything. There may be a better test method, or you might need to adjust your test method. Sometimes results are unclear, but there might be another test you can perform to demonstrate equivalence, and then you can resubmit your 510k. Possibly you were unaware of the need to perform a test, and you were unable to complete a test within the 180 days the FDA allowed for submitting additional information. The good news is you now have all the time you need.

What is similar between all four causes of the NSE letter?

In all four root causes identified above, you could benefit greatly from the pre-sub meeting. Now you have an NSE letter, and you know which of the four reasons why your submission did not result in 510(k) clearance. However, the correction to your NSE letter may not be clear. Therefore, you should consider requesting a pre-sub meeting as quickly as you can. Most companies choose not to submit a pre-sub meeting request because they don’t want to wait 60-75 days. However, sometimes pre-sub meetings are scheduled sooner. In addition, 60-75 days is not as costly as receiving a second NSE letter.

Prevent a future NSE letter by requesting a pre-sub meeting

Regardless of your corrections for the current NSE letter, you should prevent future occurrences by planning to submit a pre-sub meeting request for every submission. I try to help clients gather all the information they need without a pre-sub meeting, but each new 510k reminds me why a pre-sub meeting is so valuable. You always learn something that helps you with the preparation of your 510k.

Help with Pre-sub meeting requests

The FDA published a guidance document for pre-sub meeting requests. If you need additional help, there is a webinar on this topic.

NSE letter: A CAPA plan for your 510k process Read More »

Integrating usability testing into your design process

This article explains how you should be integrating usability testing into your design control process–especially formative usability testing.

Why you should be integrating usability testing into the design

We recently recorded an updated usability webinar and released a usability procedure (SYS-048) with help from Research Collective–a firm specializing in human factors testing. After listening carefully to the webinar, and reading through the new usability procedure, I felt we needed to update our combined design/risk management plan to specify formative testing during phase 3 and summative (validation) testing during phase 4 of the design process. This is necessary to ensure your usability testing is interwoven with your risk management process. Integrating usability testing into all phases of your design process is critical–especially design planning (phase 1), feasibility (phase 2), and development (phase 3).

Click here to subscribe to our blog feed

Integrating usability testing into your design plan helps identify issues earlier

During the usability training webinar, Research Collective provided a diagram showing the various steps in the usability engineering process. The first five steps should be included in Phases 1 and 2 of your design process. Phase 1 of the design process is planning. In that phase, you should identify all of the usability engineering tasks that need to be performed during the design process and estimate when each activity will be performed. The first of these usability activities is the identification of usability factors related to your device. Identifying usability factors is performed during Phase 2 of your design process before hazard identification.

Identifying usability issues during phase 1 - design planning

Before performing hazard identification, which should include identifying potential use errors, you need to identify five key usability elements associated with your device:

  1. prospective device users during all stages of use must be defined
  2. use environments must be identified
  3. user interfaces must be identified
  4. known use errors with similar devices and previous generations of your device must be researched
  5. critical tasks must be described in detail and analyzed for potential use errors

Defining users must include the following characteristics: physical condition, education, literacy, dexterity, experience, etc. Use environment considerations may consist of low lighting, extreme temperatures or humidity, or excessive uncontrolled motion (e.g., ambulatory devices). User interfaces may include keyboards, knobs, buttons, switches, remote controllers, or even a touch screen display.

Often the best reason for developing a new device is to address an everyday use error that is inherent to the design of your current device model or a competitor’s product. Therefore, a thorough review of adverse event databases and literature searches for potential use errors is an important task to perform before hazard identification. This review of adverse event data and literature searches of clinical literature are key elements of performing post-market surveillance, and now ISO 13485:2016 requires that post-market surveillance shall be an input to your design process.

Finally, the step-by-step process of using your device should be analyzed carefully to identify each critical user task. User tasks are defined as “critical” for “a user task which, if performed incorrectly or not performed at all, would or could cause serious harm to the patient or user, where harm is defined to include compromised medical care.” Not every task is critical, all critical tasks must be identified, and ultimately you need to verify that each critical task is performed correctly during your summative (validation) usability testing.

Evaluating Risk Control Options – Formative Usability Testing in Phase 3 (Development)

Once your design team has conducted hazard identification and identified your design inputs (i.e., design phase 2), you will begin to evaluate risks and compare various risk control options. Risk control option analysis requires testing multiple prototype versions to assess which design has the optimum benefit/risk ratio. This is an iterative process that involves screening tests. For any use risks you identify, formative usability testing should be performed. Sometimes the risk controls you implement will create new use errors or new risks of other types. In this case, you must compare the risks before implementing a risk control with risks created by the risk control.

Formative Usability Testing during phase 3 - the development phase

Ideally, each design iteration will reduce the risks further until all risks have been eliminated. The international risk management standard (ISO 14971) states that risks shall be reduced as low as reasonably practicable (ALARP). However, the European medical devices regulations require risks to be reduced as far as possible, considering the state-of-the-art. For example, all small-bore connectors in the USA are now required to have unique connectors that are incompatible with IV tubing Luer lock connections to prevent potential use errors. That requirement is considered “state-of-the-art.” If your device is marketed in both the USA and Europe, you will need to reduce errors as far as possible–before writing warnings and precautions in your instructions for use.

Reaching the point where use errors cannot be reduced any further may require many design iterations, and each iteration should be subsequently evaluated with formative usability testing. Formative testing can be performed with prototypes, rather than production equivalents, but the formative testing conditions should also address factors such as the use environment and users with different levels of education and/or experience. Ultimately, if the formative testing is done well, summative (validation) testing will be a formality.

Risk Control Effectiveness During Phase 4 – Summative Usability Testing during Verification

Once your team freezes the design, you will need to conduct verification testing. This includes integrating usability testing into the verification testing process. Summative (validation) testing must be performed once your design is “frozen.” If you are developing an electrical medical device, then you will need to provide evidence of usability testing as part of your documentation for submission to an electrical safety testing lab for IEC 60601-1 testing. There is a collateral standard for usability (i.e., IEC 60601-1-6). For software as a medical device (SaMD), you will also be expected to conduct usability testing to demonstrate that the user interface does not create any user errors.

Summative (validation) Usability Testing in phase 4

When you conduct summative (validation) testing, it is critical to make sure that you are using samples that are production equivalents rather than prototypes. Also, it is crucial to have your instructions for use (IFU) finalized. Any residual risks for use errors should be identified in the precautions section of your IFU, and the use of video is encouraged as a training aid to ensure use errors are identified, and the user understands any potential harm. When the summative testing is performed, there should be no deviations and no use errors. Inadequate identification of usability factors during Phase 2, or inadequate formative testing during Phase 3, is usually the root cause of failed summative testing. If your team prepared sufficiently in Phase 2 and 3, the Phase 4 results would be unsurprisingly successful.  

Additional Training Resources for Usability Engineering

The following additional training resources for usability engineering may be helpful to you:

Integrating usability testing into your design process Read More »

ISO 14971 Risk Management Updates in ISO/DIS 14971:2018

This article describes updates being made to the ISO 14971 Standard in the new draft version released for comment in July 2018.

There are two versions of ISO 14971 that are currently available. The first is the international version: ISO 14971:2007. The second is the European normative version: EN ISO 14971:2012. There is also a new draft being created by the TC210 committee for release in 2019.

Click here to subscribe to our blog feed

Explanation of the different versions of the ISO 14971 standard

In 2000, the first edition of ISO 14971 was released as the international standard for risk management of medical devices. In 2007, the second edition of ISO 14971 was released. When new international standards are released, a European normative version is also released. The “European Norm” or EN version is intended to identify any gaps between the international standard and the requirements of the applicable European directives (i.e., the MDD, AIMD, and the IVDD). These gaps historically were included in the ZA annex at the end of the EN version. However, in 2009 this annex was split into three annexes (i.e., ZA, ZB, and ZC) to address each of the three directives separately. In reality, the 2009 annex only differed concerning the directive referenced. In 2012, a new EN version was released. This new standard included seven deviations, which were controversial. These deviations were intended to identify contradictions between the directives and the international standard, but the interpretations were not agreed with by companies or most of the Notified Bodies. Ultimately, the seven deviations were required to be addressed in the risk management files for any medical device that was CE Marked.

What changed between ISO 14971:2007 and ISO/DIS 14971:2018?

The TC210 working group assigned to update the ISO 14971 standard (JWG1) was tasked with improving guidance for the implementation of ISO 14971. Still, the committee was also tasked with making these improvements without changing the risk management process. Also, the committee was asked to move the informative annexes at the end of ISO 14971 from the standard to the guidance document ISO/TR 24971. Therefore, in July, the committee released a draft for comment and voting. Draft versions are identified with the prefix “ISO/DIS.” The ISO/DIS 14971 standard released in July has only three annexes: A) Rationale for the requirements, B) Risk management process for medical devices, and C) Fundamental risk concepts (formerly Annex E). The other seven annexes were moved to the draft of ISO/TR 24971. The reason stated for moving these Annexes to the guidance document was to make future revisions to the guidance easier to implement because it is a guidance rather than a standard. However, there were also some objectionable recommendations in the informative annexes that were the subject of deviation #3—ALARP from Annex D.8 vs. “As far as possible,” in the first indent of section 2 of Annex I in the MDD.

Although the committee was tasked to make improvements in the implementation of ISO 14971 without changing the process, the new draft has subtle changes in the process. Most of these changes can be identified quickly by reviewing the updated risk management flow chart provided in Figure 1. The updated flow chart now has two places where risks are evaluated. The first place is identical to the original Figure 1, but now the associated section is clarified to be specific to evaluating individual risks. The second place in the flow chart is new and specific to the evaluation of overall residual risks. The draft standard also states that different acceptability criteria and methods of evaluation may be used for each evaluation phase in the process. There have also been subtle changes to the names of process phases:

  • Section 7.4 is now “Benefit/Risk” analysis instead of “Risk/Benefit” analysis—although the draft flow chart does not reflect this.
  • Section 9 is now “Risk Management Review” instead of “Risk Management Report”
  • Section 10 is now “Production and post-production activities” instead of “Production and post-production information”

There is also more detail in the diagram under the phases for 1) risk analysis, 2) risk control, and 3) production and post-production activities.

Three new definitions are introduced in the draft standard: 3.2, benefit; 3.15, reasonably foreseeable misuse; and 3.28, state of the art. The section for identification of hazards, Clause 5.4, was reworded and expanded to consider the reasonably foreseeable sequences or combinations of events that can result in a hazardous situation. The draft standard now states that your risk management plan must also include a method to evaluate the overall residual risk and the criteria for the acceptability of the overall residual risk. In the section for risk estimation, Clause 5.5, the draft standard states that if the probability of the occurrence of harm cannot be estimated, the possible consequences shall be listed for use in the risk evaluation and risk control. The risk control option analysis priorities in section 7.1 are updated to match the new MDR, Regulation (EU) 2017/745, nearly exactly. In section 9, risk management reports were changed to risk management review, and the Clause now requires determining when to conduct subsequent reviews and when to update reports. This emphasizes the requirement to continuously update risk management documentation with input from production and post-production information. This mirrors the emphasis on continually updating post-market clinical follow-up in Regulation (EU) 2017/745, Annex XIV, Part B, Section 5, and continuously updating clinical evaluations in Regulation (EU) 2017/745, Annex XIV, Part A, Section 1.

Will the ISO 14971 version for 2019 eliminate the deviations from the MDD

Will ISO 14971:2019 address the 7 Deviations in EN ISO 14971:2012?

The new MDR, Regulation (EU) 2017/745, revised and clarified the wording of the essential requirements in the MDD. The MDR attempts to explain the requirements for risk management files of CE Marked products, but the MDR remains different from the requirements of ISO 14971. Unfortunately, because the ISO/DIS 14971 was not intended to change the risk management process of ISO 14971:2007, there will continue to be “deviations” between the MDR and standard.

Some people have tried to use ISO/TR 24971, the risk management guidance, as the official interpretation of how the risk management standard. However, the guidance is also a product of the TC210 committee, and it does not meet all requirements of the MDD or the MDR.

The new draft does, however, include changes that address some of the deviations in EN ISO 14971:2012. Below, each of the seven variations is listed, and hyperlinks are provided to other articles on each deviation.

  1. Negligible Risks – The word “negligible” was only in one location in the body of the standard as a note referring to Annex D.8. In the draft, Annex D was removed and relocated to ISO/TR 24971, and the note was eliminated from Clause 3.4—now Clause 4.4 in the draft. The draft should fully resolve this deviation.
  2. Risk Acceptability – Clause 7 was renumbered to Clause 8 in the draft. Still, the title of this Clause was also changed from “Evaluation of overall residual risk acceptability” to “Evaluation of overall residual risk.” However, if you read the Clause it still refers to determining the acceptability of risks. In note 2 of Annex ZA of the draft, it states that determining acceptable risk must comply with Essential Requirements 1, 2, 5, 6, 7, 8, 9, 11, and 12 of the Directive. The draft should fully resolve this deviation.
  3. ALARP vs. “As far as possible” – The European Commission believes that the concept of “ALARP” implies economic considerations, and some companies have used economics as a reason for not implementing certain risk controls. ALARP was eliminated from the notes in the risk management plan clause and by moving Annex D.8 to ISO/TR 24971 and adding note 1 in Annex ZA. The draft should fully resolve this deviation.
  4. Benefit/Risk Analysis – The contradiction in requirements between the International Standard and the MDD, as it relates to determining when a benefit/risk analysis must be conducted, has not been updated. The draft does not resolve this deviation. Companies that CE Mark products will need to perform a benefit/risk analysis for all residual risks and all individual risks—despite the wording of the standard.
  5. Risk Control – The contradiction in requirements between the International Standard and the MDD, as it relates to determining when risk controls must be implemented. The International Standard gives companies the option to avoid the implementation of risk controls if the risk is acceptable. At the same time, the MDD requires that risk controls be implemented for all risks unless the risk controls create additional risks that increase risks, or the risk controls do not reduce risks further. The draft does not resolve this deviation. Companies that CE Mark products will need to implement risk controls for all individual risks—despite the wording of the standard.
  6. Risk Control Options – The intent of Clause 6.2 in ISO 14971:2007 was likely to be the same as the MDD. However, the European Commission identified the missing word “construction” as being significant. Therefore, to prevent any misunderstandings, the TC210 committee copied the wording of Regulation (EU) 2017/745. The draft should fully resolve this deviation.
  7. IFU Validation – Again, to prevent any misunderstandings, the TC210 committee copied the wording of Regulation (EU) 2017/745. However, the examples of information for safety (i.e., warnings, precautions, and contraindications) were not included. Hopefully, the final version of the 3rd edition will consist of these examples. Clause 8, evaluation of overall residual risk, was also reworded to state, “the manufacturer shall decide which residual risks to disclose and what information is necessary to include in the accompanying documentation to disclose those residual risks.” The draft should fully resolve this deviation.

Recommendations for your Risk Management Process?

The most important consideration when establishing a risk management process for medical devices is whether you plan to CE Mark products. If you intend to CE Mark products, then you should write a procedure that is compliant with the current requirements of the MDD and future requirements of Regulation (EU) 2017/745. Therefore, the seven deviations should be addressed. Also, you need to maintain compliance with the current version of the standard.

I recommend creating a process based upon the newly updated process diagram in the latest draft. The process should begin with a risk management plan. For your plan, you may want to create a template and maintain it as a controlled document. It could also be part of your design and development plan template, but the plan should include each of the following risk management activities:

  1. Hazard identification
  2. Risk estimation
  3. Risk evaluation
  4. Risk control option analysis
  5. Risk control verification of effectiveness
  6. Benefit/Risk analysis
  7. Evaluation of overall residual risk
  8. Risk management review
  9. Production and post-production activities

Your procedure should also be integrated with other processes, such as 1) design control, 2) post-marketing surveillance, and 3) clinical evaluation. Your procedure must indicate the priority for the implementation of risk control options. The best strategy for ensuring risk control priorities are compliant is to copy the wording of the new EU Regulations verbatim. Your process should include performing benefit/risk analysis. You should also define your process for risk management review. Your review process should specify when subsequent reviews will be done, and when your risk management report will be updated. Finally, you should identify a post-market surveillance plan for each device or device family, and use that post-market surveillance data as feedback in the risk management process.

The one element that appears to be weakly addressed in the body of the standard is the requirement for traceability of each hazard to the other aspects of the risk management process. Although traceability is mentioned in Clause 3.5 of the 2nd edition, and Clause 4.5 of the draft 3rd edition of ISO 14971, that is the only place is mentioned in the body of the standard. Traceability is mentioned several more times in Annex A, but the focus seems to be on the risk management file. Companies need more guidance on how to achieve this traceability. The appropriate place for this guidance is probably in ISO/TR 24971. Still, in order to maintain this documentation, a software database will likely be critical to maintaining traceability as changes are made during design iterations and after commercialization. This type of software tool is also needed to expedite the review of risk management documentation during a complaint investigation.

Which Risk Analysis Tool should you use?

In Annex G of ISO 14971:2007 and the EN 2012 version, there are five different risk analysis tools described. The word “described” is emphasized because informative annexes are not “recommended.” The committee that created the 2nd edition of ISO 14971 wanted to provide several suggestions for possible risk analysis tools to consider. However, each tool has strengths and weaknesses. Additionally, the widespread use of the failure-mode-and-effects analysis (FMEA) tool in the automotive and aerospace industries has spread to the medical device industry, and companies seem to believe that regulators prefer the FMEA tool. This is not true. Companies should be trained in all of these tools, and training should consist of more than just reading Annex G, and the tools should be used where they are most beneficial. My recommendations are below:

  1. Preliminary Hazard Analysis (PHA) – This process is critical during the development of design inputs. It is also the most underutilized analysis tool. I have not seen a single example of this tool written in a procedure by any medical device company. I believe this process should be continuously updated as part of training new design team members and should be both product and project-specific.
  2. Fault-tree Analysis (FTA) – This process is a top-down approach to risk analysis. It is heavily utilized by transportation engineers when intersections are designed, and accidents are investigated. This tool depicts risk analysis pictorial as a tree of fault modes representing each possible root cause for failure. At each level of the tree, fault mode combinations are described with logical operators (i.e., AND, OR). The information displays the frequency of each fault mode quantitatively. Therefore, when you are investigating a complaint, the tree can be used to help identify possible fault modes that may have been the root cause of device failure. You may also be interested in the standard specific to Fault tree analysis (FTA): IEC 61025:2006.
  3. Failure Mode and Effects Analysis (FMEA) – This process is a bottom-up approach to risk analysis. The automotive and aerospace industries heavily utilize it. This tool systematically lists all failure modes in groups organized by component. Risks are estimated based upon the severity of effect, probability of occurrence, and detectability. Over time, the FMEA process split into three tools: 1) process FMEA (pFMEA), 2) design FMEA (dFMEA), and 3) use FMEA (uFMEA). The first is ideal for analyzing and reducing risks associated with the manufacturing of devices. In particular, the detectability factor can be linked closely with process validation. The second evolved from the realization that the detection of a risk after the device is in the user’s hands does not reduce risk. A risk reduction only occurs if detectability is proactive. Therefore, this was stated in Annex G.4, and companies began to eliminate detectability and continued to use FMEA as their primary tool. Due to the widespread familiarity with the FMEA tool, usability FMEAs became popular for documenting risks associated with the use of a device. Unfortunately, the only real advantages of a dFMEA and uFMEA are familiarity with the tool. You may also be interested in the standard specific to FMEA: IEC 60812:2018.
  4. Hazard and Operability Study (HAZOP) – In addition to the risks of using devices, there are also risks associated with the production of devices. Processes related to coating, cleaning, and sterilization are all processes that typically involve hazardous chemicals. The chemical and pharmaceutical industries use HAZAP as a tool to analyze these process risks and prevent injuries. You may also be interested in the standard specific to HAZOP: IEC 61882:2016.
  5. Hazard Analysis and Critical Control Point (HACCP) – This process is primarily used by the food industry to prevent the spread of contaminated food supplies. Even though medical device manufacturers do not typically use it, it should be considered as a tool for managing the supply chain for devices. This model is useful when manufacturing is outsourced, or secondary processing is conducted at second and third-party suppliers. Since many FDA inspectors started in the food industry as inspectors, this is also a method that is supported by the FDA as a risk control process for outsourced processes.

How to document your risks?

For simple devices, risk management documentation is a burdensome task. For complex devices, a spreadsheet could include hundreds of lines or more than even one thousand individual lines. Also, the requirement for traceability requires additional columns in a table. Therefore, it becomes nearly impossible for you to include all the required information on a page that is 11 inches wide. If you expand your page to 17 inches wide, the size of your font will need to be very small. If you make a change, your spreadsheet can be challenging to update quickly. You could purchase a 43” widescreen TV for your monitor, or you can use dual monitors for your display, but changes remain challenging to implement without a mistake.

You need to stop relying upon spreadsheets. Use a database, and don’t use Microsoft Access. Purchase a database that is designed to document design controls and risk management traceability. If your company has software expertise, develop your software tool to do this. You should also design standardized templates for exporting your reports. By doing this, it will only take minutes to create an updated report when you make design changes. If you describe the risk management activities as notes in your software, the description of these activities can also be automatically converted into summary pages for each report summarizing that risk management activity. You can even prompt the user to answer questions in the software to populate a templated document. For example, you can prompt users to input subsequent updates of your risk management reviews, and that can be automatically converted into a summary paragraph. This reporting capability is especially helpful when responding to FDA review questions asking for cybersecurity risks.

Additional Training Resources for ISO 14971

The risk management training webinar has been completely rewritten for the second time (i.e. the first time was on October 19, 2018). The newest version will be a two-part webinar series. Part one of two will focus on Clauses 1 through 7.1 of the ISO 14971:2019 standard. Part two of two will focus on Clauses 7.2 through 10. We selected Clause 7.2 to begin the second part of this webinar series, because it marks the beginning of the verification of the risk controls your company has implemented (i.e. – Post “Design Freeze”). Part 1 will be hosted live on March 29, 2022 @ 9-10:30 am EDT, and Part 2 will be hosted live on April 5, 2022 @ 9-10:30 am EDT. Both sessions will be recorded if you are unable to participate in the live sessions.

SYS-010, Medical Device Academy’s Risk Management Procedure, is compliant with EN ISO 14971:2019. The procedure includes templates for documentation of design risk management and process risk management. The procedure is also compliant with ISO/TR 24971:2020 and Regulation (EU) 2017/745. Both the two-part risk management training webinar, and the risk management procedure, are included in Medical Device Academy’s turnkey quality system. 

ISO 14971 Risk Management Updates in ISO/DIS 14971:2018 Read More »

Purchasing Controls and Supplier Qualification

This article identifies the requirements for purchasing controls and supplier qualification procedures, as well as best practices for implementation.

new supplier qualification is one of the most important aspects of purchasing controls

Purchasing Controls

Sourcing suppliers in the medical device industry is not as simple as going on the internet and finding your material and purchasing it. As part of a compliant quality management system, purchasing controls must be in place to ensure that quality products and materials are going into your device and that any service providers that your company uses in the production of your product or within your quality management system are qualified.

Click here to subscribe to our blog feed

ISO 13485 Requirements

In light of that, ISO 13485:2016 sections 7.4.1 Purchasing process, 7.4.2 Purchasing information, and section 7.4.3 Verification of purchased product outline the purchasing controls for medical device manufacturers. The following are requirements for the evaluation and selection of suppliers:

  • The organization must have established criteria for the evaluation and selection of suppliers.
  • The criteria need to evaluate the supplier’s ability to provide a product that meets the requirements.
  • It needs to take into consideration the performance of the supplier.
  • It must consider the criticality and the effect that the purchased product may have on the quality of the medical device.
  • The level of supplier assessment and monitoring should be proportionate to the level of risk associated with the medical device.

Maintaining Purchasing Controls

To start, in the most basic sense, purchasing controls involve procedures that ensure you are only purchasing from suppliers who can meet your specifications and requirements. The best way to keep track of your qualified suppliers is to maintain an Approved Supplier List (ASL). You should only purchase products or services that affect your product or quality management system from companies on the ASL (you would not necessarily need to qualify things like office supplies or legal assistance through purchasing controls).

When used effectively, the Approved Supplier List can be a great tool to manage the key facets of purchasing control and keep track of supplier monitoring. Items that you can capture on the ASL include:

  • Supplier Name
  • Scope of Approved Supplies
  • Contact Information
  • Status of Approval (Approved, Pending, Unapproved, etc.)
  • Qualification Criteria
  • Supplier Certification and expiry dates
  • Monitoring Requirements/Activities
    • Date of Last Review
    • Date of Next Review

The first step in your purchasing procedure should involve checking to see if the supplier is under active approved status on the ASL. The second step will be to ensure that you are purchasing an item/service that is within the scope of approval of that supplier. If you have not approved the supplier, or the intended purchase is beyond the scope of that supplier, your purchaser will need to go through the necessary channels to add the supplier to the ASL or modify their scope on the ASL.

Supplier Qualification Criteria

As required by the FDA, the level of supplier assessment should be proportionate to the level of risk associated with the medical device. The FDA is not prescriptive about the use of specific qualifications or assessments for different types of suppliers, so that is up to your company to determine. This is a somewhat grey area but based on years working with companies and suppliers, as well as participating in FDA and ISO 13485 audits, there are some general expectations of vendor qualifications that we have observed and would recommend.

It is good practice to have a form or template that guides your supplier evaluation process. Using input from engineering and QA to first determine the level of risk and the requirements of that supplier, and then base your qualification plan on that information. If you have a higher risk supplier who may be supplying a critical component to your device, or providing a critical service such as sterilization, then your qualification process will be much more involved.

Here is an example of two different levels of criteria based on the type of supplier (the intent is not for the following items to be rules, and your company is responsible for determining the adequate acceptance criteria for suppliers, but this is a general example of what you may expect).

  • Critical Custom Component Supplier
    • ISO 13485 Certification
    • On-site audit of supplier’s facility
    • References
    • Provides Certificates of Analysis (CoA)
    • A written agreement that the supplier will communicate with the company regarding any changes that could affect their ability to meet requirements and specifications.
    • You validate a production sample, and it meets requirements
  • Non-Critical Consumable Supplier
    • Product available that meets the needs of the company.
    • An associate has previously used by an associate who recommends the supplier.
    • Adequate customer service returns allowed.

Additional Function of Supplier Evaluation Forms

The supplier evaluation form can also be used as the plan to assign responsibility and track completion and results during the initial evaluation. It can also include the plan for ongoing monitoring and control of the supplier. This evaluation form should be maintained as a quality record, and auditors will frequently ask to see supplier evaluations.

Are Supplier Audits Required as Purchasing Controls?

Also valuable, supplier audits may be included as part of an evaluation plan for a new supplier, the change of scope of a supplier, a routine audit as part of ongoing monitoring, or as part of a nonconformity investigation of a high-risk product. While it is not required by ISO 13485, nor does the FDA does specify in the CFR that you must audit suppliers, it is a very good idea to audit your critical suppliers. If an auditor or FDA inspector sees evidence that your current purchasing controls are inadequate, performing supplier audits may be forced as a corrective action.

Beyond that, you can gain so much value, and gather countless clues and important information in an audit that you just cannot get without visiting your critical supplier. You can see where they plan to/are making/cleaning/sterilizing/storing your product. Talk to the people on the line, are they competent and trained? Does the company maintain their facility well? How secure is it? Do they maintain adequate records and traceability? Have there been any nonconformities relating to your product that have been detected? Etc.

Supplier audits should also include evaluation of the procedures, activities, and records of the supplier that could have an impact on the product or service they are providing your company. If it is not the first audit of the company, you should be sure to review the previous audit report findings and ensure the company has addressed any nonconformities, review supplier performance data, information about any changes that may have occurred at the supplier since your last visit, etc.

Record Maintenance and Ongoing Evaluation of Suppliers

No matter the method of supplier qualification, it is best practice to maintain supplier files that contain useful information relative to the supplier that may include:

  • The original supplier qualification form
  • Supplier certificates
  • References
  • Audit reports
  • Subsequent performance evaluations
  • Expanded scope qualifications
  • Supplier communications
  • Current contact information
  • Copies of any non-conforming material reports related to the supplier, etc.

ISO 13485 requires monitoring and re-evaluation of suppliers, and maintaining detailed supplier files will assist in meeting this requirement, and will help in the feedback system to identify and recurring problems or issues with a supplier. On a planned basis, whether that is annually, or every order (dependent on the criticality of the product), your company should conduct a formal supplier evaluation to determine whether the supplier has continued to meet requirements – In general, annual supplier reviews are standard. Additionally, you must specify this frequency in your procedure (auditors will look for what period you specify in your procedure, and then will check your ASL to make sure all of your suppliers have been reviewed within that timeframe).

During the supplier evaluation, if you find there have been issues, you need to determine and weigh the risks associated with staying with that supplier, and document that in the supplier file. If you determine the supplier should no longer be qualified, then you must also indicate on the ASL that the company no longer approves of the supplier.

Making the Purchase

When you have verified your supplier is approved on the ASL, you are authorized to purchase a product. Engineering is usually responsible for identifying the product specifications, requirements for product acceptance, and adequacy of specified purchasing requirements before communication to the supplier. The specifications may be in the form of drawings or written specifications. Additional information communicated to the supplier should also include, as applicable, an agreement between your company and the supplier that the supplier will notify you before the implementation of changes relating to the product that could affect its ability to meet specified purchasing requirements. When the first batch of product is received from a particular supplier, it is a good idea to verify that the product performs as intended before entering into production with new material or components.

Supplier Nonconformity

From time to time, you may encounter issues with a supplier. Sources of nonconformity include incoming inspections, production nonconformities, final inspection, or customer complaints. You must notify your supplier of the nonconformity and record their response and assessment. Depending on the level of criticality of the vendor, it is reasonable to require them to perform a root cause analysis to determine and alleviate the cause of failure. You should also request documentation of an effectiveness check to ensure the supplier has taken corrective actions. You should maintain copies of supplier nonconformity reports in the supplier file, and discuss nonconformities during ongoing supplier evaluations.

If the supplier does not cooperate or fails to address the nonconformity in an acceptable manner, or if there is a pattern of nonconformities with the vendor, then you should disqualify the supplier, and indicate that the supplier is “not approved” on the ASL.

Purchasing Controls Procedures You Might Need

Medical Device Academy developed a Supplier Qualification Procedure, Purchasing Procedure, and associated forms that will meet purchasing controls regulatory requirements for ISO 13485:2016 and 21 CFR 820.50. These procedures will help you ensure that goods and services purchased by your company meet your requirements and specifications. If you have any questions or would like help in developing a custom procedure or work instructions that meet your company’s unique needs, please feel free to email me or schedule a call to discuss.

Purchasing Controls and Supplier Qualification Read More »

Implementing Procedures for CAPA, NCMR & Receiving Inspection

Learn how to implement procedures for a new ISO 13485 quality system. Specifically, CAPA, NC product, and incoming inspection. This is the second in a series. The first month of procedure implementation was covered in a previous article titled, “How to implement a new ISO 13485 quality system plan in 2016.”

implementing procedures

Typically, I recommend implementing a new ISO 13485 quality system over six months. Still, recently I a few clients have requested my assistance with implementing a quality management system within four months. In November, I wrote an article about implementing a new ISO 13485 quality system. That article described implementing procedures for the first month. Specifically, the implementation of the following procedures was covered:

  1. SYS-027, Purchasing
  2. SYS-001, Document Control
  3. SYS-002, Record & Data Control
  4. SYS-004, Training & Competency
  5. SYS-011, Supplier Quality Management
  6. SYS-008, Product Development
  7. SYS-010, Risk Management
  8. SYS-006, Change Control

These eight procedures are typically needed first. This article covers the implementation of the next set of procedures. During this month, I recommend conducting company-wide quality management system training for the ISO 13485 and 21 CFR 820.

Click here to subscribe to our blog feed

Receiving Inspection Procedures

During the first month, procedures for purchasing components and services are implemented. As these products are shipped and received by your company, you need to create records of incoming inspection. It is not sufficient to merely have a log for receiving inspection. You need records of the results of the inspection. You may outsource the inspection activities, but receiving personnel must review the records of inspection for accuracy and completeness before moving product to your storage warehouse or production areas. Even if the inspection is 100% outsourced, it is still recommended to verify the inspection results independently on a sampling basis periodically. This should be a risk-based sampling that takes into account the importance of the item being inspected and the existence of in-process and final inspection activities that will identify potential nonconformities.

The most challenging part of this process is typically identifying inspection procedures and calibrated devices for inspection. Your company must find a balance between inspections performed by suppliers, incoming inspection, in-process inspection, and final inspection. Each of these process controls requires time and resources, but implementation should be risk-based and take into account the effectiveness of each inspection process–as determined by process validation. Sample sizes for inspection should also be risk-based.

Implementing Procedures for Identification and Traceability

The lot or a serial number of components must be identified throughout product realization–including incoming inspection, storage, production, final inspection, and shipping. In addition to determining what things are, you must also identify the status of each item throughout the product realization process. For example:

  • Is the product to be inspected or already inspected?
  • After the inspection, is product accepted or rejected?
  • Which production processes have been completed?
  • Is the product released for the final shipment?

The procedure for identification and traceability should be implemented immediately after the purchasing process, implemented during 1st month, because traceability requirements should be communicated to suppliers as part of supplier quality agreements and as part of each purchase order.

Initially, when this process is implemented, there is a tendency to complete forms for every step of the process and to distribute copies of the forms to communicate status. Completing forms and copying paperwork requires labor and adds no value. Therefore, learn manufacturing methods and visual indicators such as color-coding are recommended as best practices for identifying products and their status.

CAPA Procedures

When a product is identified as nonconforming, corrective actions need to be implemented to prevent a recurrence. Procedures need to include the requirement for planning corrective actions, containing a nonconforming product, correcting nonconformities, and implementing actions to prevent any future nonconformities. These procedures also need to address negative trends to prevent nonconformities before the product is out of specification (i.e., preventive actions). Procedures also need to provide guidelines on how to verify the effectiveness of corrective and preventive actions. Initially, the actions implemented will be specific to a purchased product that is received and rejected. However, over time data analysis of process monitoring and internal auditing will identify additional corrective and preventive actions that are needed.

The effectiveness of CAPA processes, in general, requires three key elements:

  1. A well-designed CAPA form
  2. Proper training on root cause analysis
  3. Performing effectiveness checks

In the CAPA training provided during the second month, the best practices for CAPA form design are covered. The training includes several methods for root causes analysis too. Finally, the training emphasizes using quantitative measurements to verify the effectiveness of corrective actions. It is recommended to identify the quantitative acceptance criteria for an effective corrective action before initiating actions to ensure that the actions planned are sufficient to prevent a recurrence.

Monitoring Your Procedure Implementation Process

As indicated in the previous article, I recommend using quantitative metrics to track the progress of procedure implementation. For example:

  1. % of procedures implemented,
  2. duration of the document review and approval process, and
  3. % of required training completed.

Implementing Procedures for ISO 13485:2016

If you already have a quality system in place, you are implementing procedures that are modified for ISO 13485:2016 compliance; some of the same lessons apply. If you are interested in ISO 13485:2016 training, you can register for an on-demand two-part course (i.e., 1-hour Stage 1 video, and 2-hour Stage 2 video) on the ISO 13485 page. The training includes two quizzes for training effectiveness.

Implementing Procedures for CAPA, NCMR & Receiving Inspection Read More »

FDA 483 Inspection Observations Pareto Chart for FY 2015 Data

This article presents Pareto Analysis of FDA 483 inspection observations from FY 2015 and compares with historical data.

FY 2015 Pareto Analysis of FDA 483 inspection observations

Method of Data Analysis for FDA 483 Inspection Observations

The FDA posts Excel spreadsheets on the website to download data for FDA 483 Inspection Observations. These spreadsheets include inspection results for all the divisions of the FDA. To perform data analysis for FY 2015 results, I deleted the sheets that were not specific to medical device manufacturer inspections (i.e., only used data from CDRH). I sorted the data by the regulation that was referenced. For example, all the sub-clauses for 21 CFR 803 were combined into one category for the Pareto analysis. The combined categories were then sorted from the most frequent 483 inspection observations to the least frequent 483 inspection observations. The data was then added to the graph that I produced in February 2014 using FY 2013 results as a second data set. The resulting graph is shown above.

Click here to subscribe to our blog feed

Comparison of FDA 483 Inspection Observations between FY 2013 and FY 2015

For MDR Compliance (i.e., 21 CFR 803), there was a slight increase in the number of 483 observations issued from FY 2013 to FY 2015. However, the difference was only a 1% increase from 6.2% to 7.2% of the total number of 483s issued. There was an even smaller increase in the number of findings related to purchasing controls (i.e., 5.6% increased to 6.1%). I noticed a slight drop in the number of findings related to design controls, CAPA, and complaint handling. However, the overall trend for FY 2013 and FY 2015 is essentially the same.

There are two other categories where an increase was observed: 1) process validation increased by 0.7% from 4.8% to 5.5%, and 2) control of nonconforming product increased 0.8% from 4.3% to 5.1%. These areas are important. Control of nonconforming product is one of the major sources of CAPAs and often results in design changes. Therefore, FDA inspectors are reviewing your data for a nonconforming product during inspections to help them identify potential CAPAs and design changes that may have been made. The typical sequence is 1) nonconformity, 2) investigate nonconformity as part of a CAPA, and 3) initiate a design change as a corrective action.

Process validation is a completely different area that is separate from CAPA, complaint handling, and MDRs. However, inadequate process validation is a common root cause of nonconformities. Therefore, inspectors often follow an audit trail from a nonconforming product record back to a process change that was implemented but inadequately validated. Thus, an increased focus on nonconformities may be the reason for an increase in FDA 483 inspection observations related to process validation.

So what’s the big deal?

This proves that the FDA inspectors continue to be predictable. The “playbook” for FDA inspections is the QSIT Manual. It hasn’t changed since 1996. Yet, companies continue to be shocked and amazed by FDA inspectors.

Additional Resources

If you want to learn how to prepare for FDA inspections, I recorded a webinar you can download. I recorded the webinar in March of 2026, but it’s been a couple of years, and I’ve learned a few new tricks. Therefore, I’m going to re-record the webinar and update it for lessons learned. I’ll even share a few tools and approaches to avoid findings and reduce the risk of warning letters. If you already had an FDA inspection and you need to respond to FDA 483 inspection observations, we have a training video for that too.

Until then, I am working on a webinar specific to medical device reporting. Many companies have still not updated their MDR procedures to reflect the eMDR process using electronic submissions gateways. Therefore, I’m releasing an updated procedure for MDRs, and I am offering a webinar bundle to train people on how to comply with 21 CFR 803 and the procedure. You might also be interested in my previous webinar specific to control of the nonconforming product.